VICTAULIC Y317806RBH 2 UMC MANIFOLD RH W/CTRL VLV & HOSE
Victaulic® Right Hand Universal Manifold Check Assembly, Series: UMC, 2 in Nominal, Connection Type: Grooved x Grooved, Mirrored Port, 300 psi, 80 to 270 gpm Flow Rate, 8 ft L Inlet to Outlet, 1/4 in Opening, Ductile Iron Body, 40 deg F, 11-1/2 in W x 11.9 in H, Domestic Victaulic, Right Hand Universal Manifold Check Assembly, UMC, Y317806RBH The Globe Series "UMC" universal manifold check is a first of its kind, UL listed and FM approved, complete floor control station or shotgun riser assembly. It is pressure rated for 300 psi. It provides the most compact "footprint" while delivering all of the necessary components for your floor control station as required by the NFPA standards. With its multiple available configurations, it allows the contractor to order the suitable configuration for the site specific needs. The "UMC" universal manifold check is more than just a traditional stand-alone manifold. It serves as a complete floor control station as well as a complete shotgun riser assembly inclusive of control valve with internal supervisory switch, check valve, flow switch, test and drain assembly, adjustable pressure relief valve assembly pre-piped to drain, supply gauge (4 in, 6 in and 8 in) and system gauge (1-1/4 in through 8 in). The "UMC" universal manifold check replaces the need to order individual "Riser Manifolds" plus control valves, check valves, and relief valve kits as all of these components are integrated into the one compact design, saving space as well as the labor to connect these separate components. For sizes 3 in and smaller, an 18 in long stainless steel braided flexible hose is included with the UMC for connecting the test and drain valve to a drain stack. The design takes into account both "left-hand" and "right-hand" orientations. The UMC may be utilized to meet the NFPA 13 requirements for floor control valve assemblies where there are multistory buildings exceeding two stories in height requiring zoning by floor or whenever separate control and floor zoning is specified. The UMC has been engineered with space savings in mind for those commonly installed applications in stairwell landings and small alcoves. All UMC assemblies include the NFPA 13 required listed pressure relief valve which is pre-piped to drain. The relief valve is preset for 175 psi and is adjustable to 310 psi for high pressure system conditions. In addition to the relief valve, the UMC is equipped with a test and drain valve. The test and drain valve contains a test orifice of K2.8, K4.2 and K5.6 for 1 in, 1-1/4 in and 2 in respectively so that it may be utilized for flow testing any system with sprinklers having K-factors of that size or larger.
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.